/15 3900 Report a question What's wrong with this question? You cannot submit an empty report. Please add some details. 123456789101112131415 Master Your California C10 Electrical Exam with Our Premium Practice Test! Our timed practice test mirrors the real PSI exam, helping you master the material and manage test-day stress. With 1,100+ questions, no two exams are the same. Why settle for a PDF when you can simulate the real thing? Take the test now and walk into your exam ready to pass! Exam Details Time Limit 30 minutes Questions 15 randomly selected Question Bank 450 unique questions Test-Taking Tips Use your time wisely - Just 2 minutes per question Not sure about an answer? Use the bookmark feature to flag questions for review Cost per attempt: Unlimited Free Tests Format: You can use your book for this exam, but the actual exam is closed book. Why waste time randomly studying the wrong material? Our practice exams teach you to efficiently locate crucial information in the code book – an essential skill for both passing the exam and succeeding in your plumbing career. Each question is strategically designed to improve your speed and accuracy with the reference materials you'll use on test day. Don't let code book navigation slow you down on exam day. Start practicing with real exam-style questions today! Please enter your following information to get started: 1 / 15 A phone line test for polarity is the yellow and black wire line test where the _______. A) red light indicates wires are reversed B) yellow light indicates AC voltage short C) green light indicates wiring is neutral D) All of the above For the yellow and black wire polarity phone line test, a yellow light indicates AC voltage on the line, the green light indicates the wiring is good, and the red light indicates the wires are reversed. 2 / 15 A multiware branch circuit protected by fuses may supply only _________. A) half line to line loads and half line to neutral loads B) half line to neutral loads to full or trip line to other loads C) line to line loads D) line to neutral loads NEC Section 210.4(C) requires that multiware branch circuits supply only line to neutral loads. 3 / 15 If the GFI trips, it may be due to __________. A) improper wiring B) a ground fault C) a faulty GFI D) All of the above If the GFI does not trip after checking the product and rewiring, add fixtures back onto the circuit one by one until the problem is located. 4 / 15 A 240-volt circuit has a current flow of 20 amperes. How much resistance (ohms) is connected to the circuit? A) 3 ohms B) 6 ohms C) 9 ohms D) 12 ohms R = E/I; 240/20 = 12 ohms 5 / 15 When a branch circuit feeds both noncontinuous and continuous loads, the curcuit must be sized to accommodate 100 percent of the noncontinuous load plus what percent of the continuous load? A) 110 percent B) 115 percent C) 120 percent D) 125 percent The rating of branch circuits serving continuous loads shall be not less than the noncontinuous load plus 125 percent of the continuous load. 6 / 15 A phone line test, called the red and green wire polarity test indicates the red and green connections are reversed when the _______ light is on. A) green B) yellow C) red D) orange A green light indicates the wiring is good. A red light indicates the wires may be reversed and the system should be disconnected, the jack opened and connections reversed. No light indicates wires may not be securely connected. 7 / 15 The minimum size copper equipment grounding conductor for a 200-ampere circuit is ________. A) No. 3 AWG B) No. 6 AWG C) No. 8 AWG D) No. 10 AWG NEC Table 250.122 gives No. 6 AWG copper wire as the minimum size for a 200-ampere circuit. 8 / 15 _____ shall be installed in service entrances and panel feeders. A) Rigid conduit B) Flexible metal conduit C) Electrical metallic tubing D) A and C only Rigid steel conduit is used for service entrances, underground in contact with earth, in concrete slab, panel feeders, exterior of building walls, motor feeders over 10 hp, electrical equipment feeders over 10 kw, wet locations and other services and locations as required by the NEC and local codes. 9 / 15 A bare conductor is one with _________. A) several layers of thermoplastic insulation B) only one layer of insulation C) a covering that is not recognized by the NEC as electrical insulation D) no covering or insulation whatsoever A bare conductor such as a service grounding wire, has no cover or insulation. 10 / 15 According to the American Wire Gauge (AWG) system, as wires get bigger, their numbers_____ A) get smaller B) double C) get bigger D) skip a number The AWG system's principles for sizing wire include: wire numbers decreasing as wire size increases; wire numbers skipping in sequence (14,12,10, 8, 6, 4, 3, 2,1 and 0, %, % and %); the wiring system changes for wires larger than AWG %. 11 / 15 The branch-circuit overcurrent device may serve as the controller for stationary motors rated less than _______ A) 20 horsepower B) 1/8 horsepower C) 15 horsepower D) 5 horsepower Small motors (1/8 horsepower or less) may use the branch-circuit fuse or circuit fuse or circuit breaker as a means of disconnecting and de-energizing the motor. This motor must be the type normally left running (such as a clock motor) and constructed so as not to be damaged by overload. NEC Section 430.81(B). 12 / 15 A bad lamp, or faulty lamp-socket contact, may cause ________. A) other lights to dim B) fuses to blow after several minutes of operation C) the system not to light D) None of the above If the lamp is tested in other sockets and is proved to work, the lamp-socket should be tested with the voltage tester. If the socket proves to be good, turn the power off and bend the spring terminal upward to improve the contact with the lamp. 13 / 15 The terminal bar in a panelboard is connected to the neutral bar only when the panelboard is used as ________. A) motor control feeders B) low-voltage feeders C) service equipment D) machinery feeders The terminal bar used for equipment grounding (bonding) in a panelboard may be connected together only when used as service equipment. When used otherwise, the terminal bar and neutral bar must be isolated from each other. NEC Section 250.24(A). 14 / 15 Lighting loads are based on 3_____ , which includes all small appliance receptacles. A) watts per sq. ft. B) amps per each C) watts D) amps Regardless if the lighting circuits are 15-amp or 20-amp, the total will be the same. 15 / 15 The NEC allows wall-switch controlled receptacles in dwelling units in lieu of lighting outlets in all habitable rooms except _________. A) basement and attic B) living and family rooms C) bedrooms D) kitchen and bath The NEC allows a switched receptacle in all rooms, in lieu of ceiling or wall-mounted lighting fixtures, except the kitchen and bathroom. Your score isThe average score is 66% 0% Restart with New Questions Send feedback