Ace Your NEC Exam with Our Free Practice Test!

Ready to ace your electrician exam? Take our NEC 2020 Free Exam now! Face 20 questions in 40 minutes from a 100-question bank, aiming for 70% to pass. Unlimited attempts mean endless practice. Build confidence for the real test—start today and get closer to your license!

Exam Details

Time Limit
40 minutes
Questions
20 randomly selected
Question Bank
100 unique questions

Test-Taking Tips

Use your time wisely - Just under 2 minutes per question
Not sure about an answer? Use the bookmark feature to flag questions for review
Cost per attempt: Unlimited free attempts for ad-supported exams
Format: Open book, just like the real exam

Why stay stuck flipping through the code book? Learn to navigate it efficiently while testing your knowledge. Each question is designed to help you master the art of finding information quickly – a critical skill for both the exam and real-world applications.

Please enter your following information to get started:

1 / 20

CPE - bookmark empty

When cables are installed in bored holes through studs, joists or rafters, the hole shall be bored so that the hole is not less than ________ from the nearest edge of the wood member.

2 / 20

CPE - bookmark empty

All of the following are types of equipment grounding conductors, except:

3 / 20

CPE - bookmark empty

Without applying exceptions, rigid metal conduit must be supported within feet of each outlet box?

4 / 20

CPE - bookmark empty

How many No. 14 type TFE conductors can fit in a 3/4 inch piece of Electrical Metallic Tubing?

5 / 20

CPE - bookmark empty

A Class 1 signaling circuit shall not exceed ______ volts.

6 / 20

CPE - bookmark empty

What is the allowable ampacity of a type FEP No. 14 conductor?

7 / 20

CPE - bookmark empty

Alternating-Current circuits of less than 50 volts need to not be grounded where supplied by _________.

8 / 20

CPE - bookmark empty

Conductors #18, #16 and #14 used in Class 1 circuits shall be considered as protected by overcurrent devices of not over 20 amp rating except where other articles in the National Electrical Code® permit or require overcurrent protection.

9 / 20

CPE - bookmark empty

Fuse type protectors for communication circuits shall consist of an arrestor connected between:

10 / 20

CPE - bookmark empty

Conductors of Class 2 and Class 3 circuits when in the open shall be separated by not less than  _______ inches from leads of the conductors of any lighting, power or Class 1 circuits run in the same shaft.

11 / 20

CPE - bookmark empty

According to the NEC, when coaxial cables exit a fire-rated shaft on each floor, what is required?

12 / 20

CPE - bookmark empty

The minimum size equipment grounding conductor for grounding a raceway is ___________.

13 / 20

CPE - bookmark empty

Which of the following are acceptable wiring methods for the space above a suspended ceiling which is used for environmental air?

14 / 20

CPE - bookmark empty

All exposed noncurrent-carrying metal parts of computer room equipment shall be grounded except ___________.

15 / 20

CPE - bookmark empty

NPLFA circuit conductors shall not be smaller than:

16 / 20

CPE - bookmark empty

An alarm panel mounted to 5/8" dry-wall would require the working space in front of the panel to be clear for:

17 / 20

CPE - bookmark empty

In Class 2 or Class 3 systems where overcurrent protection is employed, the overcurrent protection shall not be ___________.

18 / 20

CPE - bookmark empty

Instruments with plus (+) and minus (-) signs are said to be ______.

19 / 20

CPE - bookmark empty

Communication cable type CMP can be substituted with cable __________.

20 / 20

CPE - bookmark empty

A switch is a ___________.